ARC5543/ARC4543 Advance Structures TEST No. 2 July 10, 2021
Instructor: Faris R. Habba
_____ .
Name: I.D.:
I agree not to discuss the contents of this exam until it is returned to me. I have neither given nor received any
unauthorized aid in completion of this exam. __________________________ (your signature required)
——————————————————————————————————————————————
Q1. (15 @ 2 pts = 30 pts)
1. T/F An x- braced frame typically has stiffness/stability provided by connections rather than
geometry.
2. T/F The transmission of lateral loads is related to the stiffness properties of the frame.
3. T/F A diaphragm chord on the leeward side of a structure is evaluated in compression.
4. A flexible diaphragm would transfer loading to shear walls in a equal or unequal manner.
(Circle correct response)
5. T/F Portal frames are suitable for industrial or agriculture storage buildings.
6. The Portal Method of Analysis assumes the column shear values at end columns is (larger or
smaller) than the interior columns. (Circle correct response).
7. T/F A base isolation system would be able to absorb some seismic energy but the demands on
the frame is that it is rigid.
8. T/F Shear walls should align vertically in a building structure when considering seismic
forces.
9. Indicate the appropriate evaluation method for the two frames shown in section. (see drawing
at right).
10. Which of the four options A, B, C, D would best resist seismic and winds loads?
2
11. The frame shown below is subjected to a concentrated lateral load. Which of the following is
the correct bending moment diagram?
12. The frame shown below is subjected to a uniformly distribt1ted gravity load. Which of the
following is the correct shear force diagram for the frame shown below?
13. Which of the following statements regarding a concrete floor diaphragm is correct?
a. It acts as a simple beam between the vertical lateral force resisting system
b. It distributes 1ateral forces in proportion to the relative stiffness of the elements of the vertical
lateral force resisting systems
c. It acts as a flexible diaphragm.
d. It distributes the lateral forces in proportion to the tributary width of the vertical lateral force
resisting systems
3
14. If a building is designed for a non-seismic location, which of the following effects are not
considered.?
I. Liqt1efaction
II. Tsunamis
III. Overturning
IV. Uplift
a. I and III
b. I and II
c. I, II, and III
d. I, II, Ill, and IV
15. Which of the following building elevations has the best performance in a seismic zone?
Q2. (10 @ 3 pts = 30 pts)
Show Calculations. Failure to show calculations will result in a grade of zero.
1. The following shear wall is made of 12″ concrete with a unit weight of 150 lb/ft3. It is
subjected to the applied loads shown. What is the safety factor of this wall again overturning?
a. 0.68
b. 1.46
c. 1.68
d. 0.4
4
2. What is the maximum chord force for the roof diaphragm of the figure below?
3. What is the horizontal reaction for the exterior supports of the moment frame shown below?
5
4. What is the shear force to be resisted by the interior concrete wall (B) assuming that it is three
times as rigid as the exterior walls (A) and the diaphragm is flexible?
5. What is the shear force in the left concrete shear wall (A) assuming that it is twice as rigid as
the one on the right (B), and the diaphragm is rigid?
6
6. Evaluate the stability of the frames shown.
7. Evaluate the stability of the frames shown.
8. Sketch the general shape the moment diagrams for the frame shown, no calculations needed.
7
9. What are the vertical reactions on the ground for the frame shown?
What is the horizontal reaction at the pin on the upper right?
_____________ kips
10. Sketch the general shape the moment diagrams for the frame shown, no calculations needed.
8
Q3.
Show Calculations. Failure to show calculations will result in a grade of zero.
A. Find the support reaction
(2 pts) Ax =
(2 pts) Ay =
(2 pts) By =
B. Find the brace force
(2 pts) F1 =
(2 pts) F2 =
9
Q4. (10 pts.)
Determine the base shear for the proposed six-story office building shown in Figure below. The
structure of the building consists of steel moment-resisting frames (all joints are rigid) that have
an R value of 8. The 75-ft-tall building is located in a high seismic region with SD1 = 0.4g and
SDS = 1.0g for a building supported on rock, where g is the gravitational acceleration. TL = 8 sec
per (ASCE 7 Figure 22-12), and given the deadweight of each floor is 700 kips. The occupancy
importance factor I is 1 for office buildings.
Show Calculations. Failure to show calculations will result in a grade of zero.
10
Q5. (10 pts.)
Show Calculations. Failure to show calculations will result in a grade of zero.
Calculate the vertical distribution of base shear for the proposed 3 – story apartment building as
shown in Figure below. Each floor is 10′ tall and consider typical floor load to be 125 kips and
roof load to be 91 kips.
Given: Base shear = 47.22 kips, and the fundamental period Ta(s) of the building =0.384s.
11
Q6. (10 pts.)
Show Calculations. Failure to show calculations will result in a grade of zero.
Determine the diaphragm design forces for the two-story health care facility shown below. given
the design data below.
The base shear loads per floor are given, as shown in Figure below (Fx2 = 3.5 kips, and Fx1 =
1.87 kips)
Base shear = 5.37 kips, the fundamental period Ta(s) of the building =0.56 s, SDS = 0.302 s, and
Ie = 1.25
Typical floor Total Seismic Load = 28 kips /floor
Roof total seismic load = 18 kips
Each floor is 12′ tall
ADVANCE STR T2 SUMMER 2021
Delivering a high-quality product at a reasonable price is not enough anymore.
That’s why we have developed 5 beneficial guarantees that will make your experience with our service enjoyable, easy, and safe.
You have to be 100% sure of the quality of your product to give a money-back guarantee. This describes us perfectly. Make sure that this guarantee is totally transparent.
Read moreEach paper is composed from scratch, according to your instructions. It is then checked by our plagiarism-detection software. There is no gap where plagiarism could squeeze in.
Read moreThanks to our free revisions, there is no way for you to be unsatisfied. We will work on your paper until you are completely happy with the result.
Read moreYour email is safe, as we store it according to international data protection rules. Your bank details are secure, as we use only reliable payment systems.
Read moreBy sending us your money, you buy the service we provide. Check out our terms and conditions if you prefer business talks to be laid out in official language.
Read more